Related Experiment Video
Updated: Aug 22, 2026

Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
Method development for the quantitation of ABT-578 in rabbit artery tissue by 96-well liquid-liquid extraction and
Qin C Ji1, Jun Zhang, Ramona Rodila
1Department of Drug Analysis, Abbott Laboratories, 100 Abbott Park Road, Abbott Park, IL 60064-6126, USA. Qin.Ji@abbot.com
Abstract:
Quantitative determination of drug concentrations in tissue samples can provide critical information for drug metabolism, kinetics, and toxicity evaluations. For analysis of tissue samples using liquid chromatography/tandem mass spectrometric (LC/MS/MS) detection, homogenization is a critical step in achieving good assay performance. Assay performance can be closely evaluated by spiking the drug directly into tissue samples prior to homogenization. It is especially important to include this assay evaluation for the analysis of artery tissue samples because artery tissue is very elastic, making it quite a challenge to develop an effective procedure for homogenization. An LC/MS/MS assay in 96-well format using liquid-liquid extraction was developed for analyzing ABT-578 in rabbit artery samples. Tissue quality control samples were prepared by spiking ABT-578 stock solutions directly into the tissue before homogenization. The usage of the tissue control samples gives a thorough evaluation of the sample preparation process that includes both homogenization and sample extraction. A 20% blood in saline solution was used as a homogenization solution. Calibration standards were made by spiking ABT-578 into rabbit whole blood. Blood quality control samples were also prepared by spiking ABT-578 into rabbit whole blood. These blood QC samples were used to confirm the validity of the calibration curve. A lower limit of quantitation of 0.050 ng/mL was achieved. The linear dynamic range of blood standards was from 0.050-30.3 ng/mL with the correlation coefficient (r) ranging from 0.9969-0.9996. Overall %CV was between 1.3 and 7.0%, and analytical recovery was between 98.2 and 105.8% for blood QC samples. The %CVs for tissue QC samples were between 6.7 and 13.0%, and analytical recovery after correction was between 93.5 and 114.3%.
More Related Videos
09:58Spatial Quantification of Drugs in Pulmonary Tuberculosis Lesions by Laser Capture Microdissection Liquid Chromatography Mass Spectrometry (LCM-LC/MS)
Published on: April 18, 2018
10:54Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017