Related Experiment Video
Updated: Jan 23, 2026

Author Spotlight: Enhancing Accuracy and Reproducibility in Whole Bone Bending Tests
Published on: September 1, 2023
Nanoindentation and whole-bone bending estimates of material properties in bones from the senescence accelerated
Matthew J Silva1, Michael D Brodt, Zaifeng Fan
1Orthopaedic Research Laboratories, Department of Orthopaedic Surgery, Barnes-Jewish Hospital at Washington University, 1 Barnes-Jewish Plaza, Suite 11300 WP, Saint Louis, MO 63110, USA. silvam@msnotes.wustl.edu
Abstract:
The senescence accelerated mouse, strain P6 (SAMP6) has been described as a model of senile osteoporosis. Recent results from whole-bone bending tests indicate that, despite having increased moments of inertia, SAMP6 long bones are weak and brittle compared to SAMR1 controls. In the current study we determined material properties of cortical bone from SAMP6 and SAMR1 femora and tibiae by two methods-nanoindentation and whole-bone bending tests combined with simple beam theory. We hypothesized that: (1) SAMP6 mice have reduced cortical bone material properties compared to SAMR1 controls; and (2) modulus estimated from whole-bone bending tests correlates well with modulus determined by nanoindentation. Results from nanoindentation indicated that modulus and hardness are approximately 10% higher in SAMP6 mice compared to SAMR1 controls (p<0.001), a finding consistent with slightly higher mineralization in SAMP6 bones. Despite their superior elastic and hardness properties, the bending failure properties of SAMP6 bones were markedly inferior--ultimate stress and toughness were reduced by 40% and 60%, respectively (p<0.001). Comparisons between the two testing methods for determining modulus showed poor agreement. Modulus estimated from whole-bone bending tests was not correlated with modulus determined by nanoindentation (p=0.054; r2=0.03) and the absolute values differed by a factor of five between the two methods (bending [wet], 6GPa; nanoindentation [dry], 31GPa). Moreover, relative differences between groups were inconsistent between the two methods. We conclude: (1) cortical bone from the SAMP6 mouse has increased modulus and hardness but poor material strength and toughness, which underscores the relevance of the SAMP6 mouse for studies of skeletal fragility, and (2) values of elastic modulus of bone tissue estimated using simple beam theory and bending tests of mouse femora and tibiae are inaccurate and should be interpreted with caution.
Related Concept Videos
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Bending of Material: Problem Solving
Spongy Bone
Spongy bone is more porous, and less dense compared to compact bone. It is composed of concentric lamellae that are arranged irregularly to form the trabecular network. In some bones, the spaces between trabeculae contain red marrow, where...
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
The Hyoid Bone

