In vivo galvanic currents of intermittently contacting dental amalgam and other metallic restorations
Elliott J Sutow1, Wayne A Maillet, James C Taylor
1Department of Applied Oral Sciences, Faculty of Dentistry, Dalhousie University, Halifax, 5981 University Avenue, Nova Scotia, Canada B3H 3J5. elliott.sutow@dal.ca
Objective:
It was the objective of this study to determine the magnitude of in vivo galvanic currents produced by simulating electrical contact between occluding metallic restorations, and to examine the influence of restoration age, difference in pre-contact corrosion potentials, and surface area.
Methods:
A convenience sample of 106 human subjects was studied. A Ag/AgCl micro-reference electrode and a high impedance voltmeter were used to measure the pre-contact corrosion potentials. Galvanic couples (n = 194) were next formed by simultaneously contacting occluding restorations with gold-plated probe tips for 15 s. The resulting current-time transients were measured with a zero-resistance ammeter and recorded with an electronic data acquisition program. The vast majority of couples measured contained at least one dental amalgam restoration.
Results:
Galvanic current-time transients were typically characterized by an immediate and rapid rise to a peak current, followed by an exponential decay to a much lower value at 15 s. For couples with a restoration < or = 12 mo old, median peak current and median current at 15 s were 2.26 microA (range 0.24-13.06 microA) and 0.57 microA (range 0.03-6.47 microA), respectively. For couples with a restoration >12 mo old, median peak current and median current at 15 s were 1.40 microA (range 0.24-12.09 microA) and 0.37 microA (range 0.00-3.05 microA), respectively. Couples with fresh amalgams (< or = 6 mo) generally had elevated currents (range 2.56-102.54 microA).
Significance:
A wide range of galvanic currents resulted from electrical contact of restorations in vivo. These currents were influenced by restoration age and total surface area of the galvanic couple. For amalgam-amalgam couples, the difference in the pre-contact corrosion potentials may be useful in predicting galvanic currents, when the difference is at least 24 mV.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Voltaic/Galvanic Cells
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform magnetic...
Ammeter
When an ammeter is used to measure the...
Eddy Currents
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Voltammetry: Factors Affecting Measurements
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...