Related Experiment Video
Updated: Aug 21, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
Published on: December 15, 2015
Direct detection of trace haloacetates in drinking water using microbore ion chromatography. Improved detector
1National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland.
Abstract:
A highly sensitive gradient microbore ion chromatographic method was developed with electrolytically generated hydroxide eluents for the determination of low microg/L levels of chloroacetate, bromoacetate, trifluoroacetate, dichloroacetate, chlorodifluoroacetate, dibromoacetate, trichloroacetate, bromodichloroacetate and dibromochloroacetate disinfectant by-products formed as a result of chlorination of drinking waters. The possibility of using a packed bed Dionex Atlas suppressor with a hydroxide gradient at microbore flow rates was investigated in order to reduce baseline noise levels. The Atlas suppressor displayed a very significant reduction in noise levels compared to the standard alternative ASRS Ultra suppressor, reducing noise by a factor of 15-20 in some cases, allowing trace haloacetic acids (HAs) to be seen with the direct injection of 100 microL of treated water, with prior chloride and sulfate removal. To lower detection limits even further, a solid phase extraction was employed to preconcentrate HAs, resulting in detection limits of between 0.09 and 21.5 microg/L. The method was applied to the determination of HAs in environmental samples and standard addition curves for three drinking water samples were carried out for both direct injection and preconcentration methods. R2 values in both cases were > or =0.98. Combined content for US Environmental Protection Agency regulated HAs in the three drinking water samples from Dublin City University; New Ross, Co. Wexford and Drogheda, Co. Louth were 46.5, 58.3 and 12.6 microg/L, respectively.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Ion-Exchange Chromatography
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...