Related Experiment Video
Updated: Aug 16, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Regional haemoglobin oxygen saturation during surgical haemorrhage
1Academic Surgery Unit, Education and Research Centre, South Manchester University Hospital, Southmoor Road, Wythenshawe, Manchester, UK. FCMTDR@aol.com
Aim:
Experimental research and early clinical studies have shown that regional haemoglobin desaturation, measured by near infrared spectroscopy (NIRS), follows blood loss. To further assess NIRS as a blood loss monitor, we evaluated it on patients undergoing major surgery.
Methods:
Regional haemoglobin oxygen saturation from the cerebral cortex (CsO(2)) and the left gastrocnemius muscle (PsO(2)) was continuously monitored with an INVOS 4100 NIRS oximeter in 10 patients during surgery. Haemoglobin, mean arterial pressure, arterial and central venous oxygen saturation and tension, temperature, pH and lactate concentration were also measured.
Results:
The median (IQR) blood loss was 650 (400-1 800) ml, equivalent to 16% (11-35) of the patients' blood volume. During surgery, CsO(2) fell by a mean (95% CI) of 8.4% (2-14.8) (p=0.016) and PsO(2) fell by a mean (95% CI) of 3.3% (-1.5-8.1) (p=0.16). CsO(2), but not PsO(2), correlated with the volume of blood lost (R=0.44; p=0.004), central venous oxygen saturation (R=0.52; p=0.001), and venous oxygen tension (R=0.58; p<0.001). These correlations remained significant after calculations were adjusted for changes in arterial pressure, temperature and pH.
Conclusion:
Cerebral, but not peripheral, haemoglobin oxygen saturation decreases proportionally to blood loss and correlates with measurements of systemic oxygen extraction. With further research, NIRS measurements of CsO(2) may be developed into a useful tool to monitor blood loss.
More Related Videos
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Transport in the Blood
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...