Related Experiment Video
Updated: Aug 21, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Changes in lung volume with three systems of endotracheal suctioning with and without pre-oxygenation in patients
Maria-del-Mar Fernández1, Enrique Piacentini, Lluis Blanch
1Critical Care Center, Hospital de Sabadell, Parc Tauli s/n, 08208 Sabadell, Spain. rfernandez@cspt.es
Objective:
To compare changes in lung volume, oxygenation, airway pressure, and hemodynamic effects induced by suctioning with three systems in critically ill patients with mild-to-moderate lung disease, and also to evaluate the effects of hyperoxygenation applied prior to the maneuver as suggested by some guidelines.
Design:
Prospective crossover study.
Setting:
General intensive care department of a university-affiliated hospital.
Patients:
Ten mechanically ventilated patients with mild-to-moderate acute respiratory failure.
Interventions:
Patients were ventilated in volume control mode with a mean tidal volume of 490+/-88 ml, PEEP 7+/-4 cmH2O and FiO(2) 0.36+/-0.05. Suctioning was performed sequentially with a quasi-closed system, with an open system 10 min later, and finally with a closed system. Thereafter, pure oxygen was applied for 2 min and the whole suctioning sequence was repeated in reverse order.
Measurements And Main Results:
Patients' mean PaO(2)/FiO(2) ratio was 273+/-28 mmHg. The reductions in lung volume during suctioning were similar with the quasi-closed (386+/-124 ml) and closed system (497+/-338 ml), but significantly higher with the open system (1281+/-656 ml, P=0.022). We found no significant hemodynamic adverse effects, and no significant SpO(2) reductions with all the studied suctioning techniques. Pre-oxygenation with pure oxygen did not induce additive effects in lung volume changes. With and without pre-oxygenation, lung volume returned to baseline in every patient within 10 min.
Conclusions:
Suctioning with closed and quasi-closed systems reduces the substantial losses in lung volume observed with the open system. Nevertheless, in patients without severe lung disease these changes were transient and rapidly reversible.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.