Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Virtual simulation in palliative lung radiotherapy
D M Driver1, M Drzymala, H J Dobbs
1Department of Clinical Oncology, Guy's and St Thomas' Hospital, London, UK. mail@daviddriver.co.uk
Aims:
To study the accuracy of tumour-volume localisation in a comparison of conventional and virtual simulation for palliative lung radiotherapy. To assess if three-dimensional tumour outlining is necessary for the virtual simulation process.
Materials And Methods:
Ten consecutive patients with non-small cell lung cancer underwent target localisation for palliative lung radiotherapy using conventional and virtual simulation. The treatment fields were initially marked with a conventional simulator using fluoroscopy, plain X-ray film and available diagnostic imaging. Each patient then had a computed tomography (CT), and these simulated treatment fields were reproduced within the virtual simulation planning system. Two clinicians then independently defined treatment fields using virtual simulation alone. The virtual simulation was achieved without outlining the tumour in three dimensions. The coverage of an 'ideal' CT-defined planning-target volume (PTV) was then calculated for each of the virtually and conventionally simulated fields. In addition, the amount of irradiated normal lung was measured using dose-volume histograms (DVH). Field sizes and differences in tumour volume coverage were compared.
Results:
There was significantly greater tumour volume coverage using virtual simulation compared with conventional simulation (P < 0.03). This advantage was more pronounced in tumours that were larger and those that were closer to the patient's midline. There was no statistically significant difference in the volume of uninvolved lung irradiated between the two methods.
Conclusion:
In this small sample of patients, we have demonstrated improved tumour volume coverage using virtual simulation, without increasing the volume of uninvolved lung treated. A simple but consistent method of virtual simulation for this patient group is offered as an alternative to both PTV-defined CT simulation and fluoroscopy-based conventional simulation.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...