[Determination of dextrorphan in human plasma and pharmacokinetic study]
Dan Liu1, Xiao-yan Chen, Yi-fan Zhang
1Laboratory of Drug Metabolism and Pharmacokinetics, Shenyang Pharmaceutical University, Shenyang 110016, China.
Aim:
To develop a sensitive and specific LC/MS/MS method for direct determination of dextrorphan in human plasma and to study the pharmacokinetics of dextrorphan.
Methods:
After a single oral dose of 60 mg dextromethorphan hydrobromide to 18 healthy Chinese male volunteers, the plasma concentration of dextrorphan, an active metabolite of dextromethorphan, was determined. Dextrorphan and internal standard chlorpheniramine were extracted from plasma using liquid-liquid extraction, then separated on a Zorbax Extend C18 column. The mobile phase consisted of methanol-water-formic acid (70:30:1), at a flow-rate of 0.5 mL x min(-1). A Finnigan TSQ tandem mass spectrometer equipped with electrospray ionization source was used as detector and was operated in the positive ion mode. Selected reaction monitoring (SRM) using the precursor to product ion combinations of m/z 258 to 157 and m/z 275 to 230 was performed to quantify dextrorphan. The pharmacokinetic parameters of dextrorphan were calculated by non-compartment model statistics.
Results:
The linear calibration curves were obtained in the concentration range of 0.2 - 80 microg x L(-1) Each plasma sample was chromatographed within 3.0 min. The intra- and inter-day relative standard deviation (RSD) across three validation runs over the entire concentration range was less than 8%. Accuracy determined at three concentrations (0.5, 6.0 and 70 microg x L(-1) for dextrorphan) ranged from 98.8% to 100.6%. Pharmacokinetic parameters of dextrorphan was obtained as follows: Tmax was (2.1 +/- 0.7) h, Cmax was (14 +/- 8) microg x L(-1), T1/2 was (3.8 +/- 1.8) h, AUC0-t was (60 +/- 37) microg x h x L(-1).
Conclusion:
Plasma concentration of the active metablite dextrorphan was directly determined. The method is sensitive and convenient, and is proved to be suitable for clinical investigation of dextrorphan pharmacokinetics and bioequivalence evaluation of formulations containing dextromethorphan.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
06:08Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Related Concept Videos
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Measurement of Bioavailability: Pharmacokinetic Methods
Drug Concentrations: Measurements
Plasma —...
Pharmacokinetic–Pharmacodynamic Relationship: Duration of Dose-Effect Relationship
Pharmacokinetics in Pediatric Patients: Drug Excretion