Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Relationship between contraction stress and degree of conversion in restorative composites
Fernanda C Calheiros1, Roberto R Braga, Yoshio Kawano
1Department of Dental Materials, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes, 2227, São Paulo, SP 05508-900, Brazil. fcalabro@usp.br
Objectives:
To verify the relationship between contraction stress and degree of conversion (DC) in different composites (Filtek Z250, Filtek A110, Tetric Ceram and Heliomolar).
Methods:
For the contraction stress test, composite (2 mm thick) was applied between two 5-mm diameter glass rods, mounted in a tensilometer. DC was determined by Infrared Photoacoustic spectroscopy in specimens with similar dimensions and geometry, submitted to identical curing conditions. Specimens were exposed to different energy densities (4.5, 13.5, 27.0, 54.0 and 108.0 J/cm2) by varying exposure time. Contraction stress and DC were recorded 10 min after the beginning of photoactivation. Results were analyzed by ANOVA/Tukey's test and regression analysis.
Results:
For contraction stress, the interaction between composite and energy density was significant. Stress values ranged between 0.6+/-0.2 and 2.0+/-0.3 MPa at 4.5 J/cm2, 2.3+/-0.5 and 4.3+/-0.4 MPa at 13.5 J/cm2, 3.8+/-0.5 and 5.8+/-0.9 MPa at 27.0 J/cm2, 4.2+/-0.8 and 7.9+/-0.9 MPa at 54.0 J/cm2 and 6.6+/-0.8 and 8.1+/-0.9 MPa at 108.0 J/cm2. Tetric Ceram (39+/-5.8%) showed a higher average DC than the other materials. Heliomolar (28+/-5.2%) showed an average DC similar to Filtek Z250 (32+/-6.6%) and to Filtek A110 (24+/-7.5%) regardless of the energy density level. No significant increase in DC was observed above 27 J/cm2.
Conclusions:
At high energy levels, DC had a tendency to level off earlier than contraction stress values.
Significance:
Using high energy densities may cause a significant increase in stress values, without producing a significant increase in conversion.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Transformation of Plane Stress
Stress Concentrations
Stress Concentrations
The stress concentration...
Residual Stresses
True Stress and True Strain
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...
Relation Between Tensile Strength and Compressive Strength of Concrete