Related Experiment Video
Updated: Aug 21, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Hemodynamics associated with breathing through an inspiratory impedance threshold device in human volunteers
Victor A Convertino1, Duane A Ratliff, Kathy L Ryan
1US Army Institute of Surgical Research, Fort Sam Houston, TX, USA.
Objective:
Increased negative intrathoracic pressure during spontaneous inspiration through an impedance threshold device (ITD) causes elevated arterial blood pressure in humans. This study was performed to determine whether the acute increase in blood pressure induced by breathing through an ITD is associated with increased stroke volume and cardiac output.
Design:
Randomized, blinded, controlled trial.
Setting:
Laboratory.
Subjects:
Ten women and ten men.
Interventions:
We measured hemodynamic and respiratory responses during two separate ITD conditions: 1) breathing through a face mask with an ITD (impedance of 6 cm H2O [0.59 kPa]) and 2) breathing through the same face mask with a sham ITD (control). Stroke volume was measured by thoracic bioimpedance.
Measurements And Main Results:
Compared with the control condition, ITD produced higher stroke volume (124 +/- 3 vs. 137 +/- 3 mL; p = .013), heart rate (63 +/- 3 vs. 68 +/- 3 beats/min; p = .049), cardiac output (7.69 vs. 9.34 L/min; p = .001), and systolic blood pressure (115 +/- 2 to 122 +/- 2 mm Hg [15.33 +/- 0.3 to 16.26 +/- 0.3 kPa]; p = .005) without affecting expired minute ventilation (6.2 +/- 0.4 to 6.5 +/- 0.4 L/min; p = .609).
Conclusions:
Breathing with an ITD at relatively low impedance increases systolic blood pressure by increasing stroke volume and cardiac output. The ITD may provide short-term protection against cardiovascular collapse induced by orthostatic stress or hemorrhage.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanism of Breathing I: Inspiration
The respiratory system, an essential network for breathing, comprises the conducting and respiratory zones, each playing a crucial role in the overall process of respiration. Let us explore the detailed mechanism of inspiration, or inhalation, which is the first phase of the respiratory cycle.
Pathway of Air during Inspiration
During inspiration, air enters our body through the nose or mouth and moves through the conducting zone,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...