Device-specific spatio-temporal drifts in proton resonance frequency shift thermometry at 3 T

Johannes Lindemeyer1,2, Stefanie Berger1, Mona Ayary1

  • 1Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Abstract

Related Concept Videos

¹H NMR of Labile Protons: Temporal Resolution01:10

¹H NMR of Labile Protons: Temporal Resolution

Protons bonded to heteroatoms such as nitrogen and oxygen exhibit a range of chemical shift values. This is due to the varying degree of hydrogen bonding between the proton and the heteroatom in other molecules. The extent of hydrogen bonding affects the electron density around the proton, thereby giving different chemical shift values for the protons in the proton NMR spectrum.
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Proton (¹H) NMR: Chemical Shift01:07

Proton (¹H) NMR: Chemical Shift

Organic molecules primarily contain carbon and hydrogen atoms. While all the hydrogen isotopes are NMR-active, protium or hydrogen-1 is the most abundant. It has a significant energy separation between its nuclear spin states due to its large gyromagnetic ratio. As per Boltzmann's distribution, an increase in the energy separation implies a greater excess population of nuclei available for excitation, resulting in a strong NMR absorption signal.
Absorption signals of all the protium nuclei in a...
NMR Spectroscopy: Chemical Shift Overview01:15

NMR Spectroscopy: Chemical Shift Overview

The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR01:15

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR

The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...