Related Experiment Video
Updated: Aug 21, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Arterial concentration of 99mTc-sestamibi at rest, during peak exercise and after dipyridamole infusion
Niels Peter Rønnow Sand1, Palle Juelsgaard, Karin Rasmussen
1Department of Nuclear Medicine, Skejby Sygehus, Aarhus University Hospital, DK-8200, Aarhus N, Denmark.
Abstract:
Tracers for myocardial perfusion imaging during stress should not only have high cardiac uptake but they should also have a fast blood clearance to prevent myocardial tracer uptake after the ischaemic stimulus. The present study characterize the early phase of the arterial (99m)Tc-sestamibi (MIBI) time-activity curve after venous bolus injection at rest, during peak exercise and after dipyridamole infusion. We included 11 patients undergoing angioplasty for one-vessel disease (rest study) and 20 patients evaluated for the detection of haemodynamic significant coronary stenoses by (99m)Tc-sestamibi single photon emission computed tomography (SPECT) using either bicycle exercise testing (10 patients) or standard dipyridamole testing (10 patients). Arterial blood samples of 1 ml were taken from the left femoral artery (rest study) or the right radial artery (exercise and dipyridamole studies) every 5 s during the first 5 min postinjection. In the exercise and the dipyridamole studies blood sampling were extended to include blood samples every 5 min 5-30 min postinjection. Peak MIBI concentration was lower and decrease in concentration slower after tracer injection during exercise than during dipyridamole stress testing. This may cause an underestimation of perfusion defects during exercise because of MIBI uptake after the ischaemic stimulus. The implications of the study not only refer to the choice of stress modality when using MIBI. This study also underlines the importance of considering early blood clearance in addition to regional myocardial tracerkinetic aspects such as myocardial extraction fraction when new tracers are introduced.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
