Related Experiment Video
Updated: Aug 21, 2026

Structured Exercise Regimen in Pulmonary Hypertension-Right Ventricular Failure in an Ovine Model
Published on: May 5, 2026
Interaction between nesiritide and a heparin-coated pulmonary artery line during an infusion for decompensated heart
Steven A Baroletti1, Heather D Wahlstrom
1Department of Pharmacy Services, Brigham and Women's Hospital, Boston, MA 02115, USA. sbaroletti@partners.org
Study Objective:
Because it is known that intravenous nesiritide is not compatible with unfractionated heparin, we sought to determine the effect that heparin coating on a pulmonary artery catheter may have on the efficacy of a nesiritide infusion.
Methods:
The efficacy of a nesiritide infusion given through a heparin-coated pulmonary artery line was compared with that of a nesiritide infusion administered in the same patient through a heparin-free peripheral line.
Results:
The rate of infusion was titrated to maintain consistent hemodynamic parameters. When nesiritide was administered through a heparin-coated line, the infusion rate escalated from 0.01 microg/kg/minute to 0.07 microg/kg/minute. After the route of administration was switched to a heparin-free line, the same hemodynamic parameters were maintained. The heparin-free line made it possible to reduce the infusion rate by 57.1% over the next 24 hours to 0.03 microg/kg/minute.
Conclusion:
The interaction of nesiritide with heparin-coated pulmonary artery lines has the potential to be clinically significant. Clinicians should be educated about this potential interaction. Nesiritide should be infused only through heparin-free lines.
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Cardiac Catheterization IV: Nursing Management
Heart Failure V: Medical Management
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Cardiopulmonary Resuscitation IV: Pharmacological Management