Dual-energy digital mammography utilizing stimulated phosphor computed radiography
1FAXIL, The Wellcome Wing, The General Infirmary, Leeds, UK.
Abstract:
Dual-energy subtraction is a radiographic technique for the acquisition of a material selective image by the weighted subtraction of low- and high-energy digital X-ray images. This is achieved by exploiting the energy dependence of the X-ray attenuation components in the image. This can allow the removal of background morphology to enhance the presentation of otherwise obscured details. The detection of microcalcifications in a mammogram by dual-energy techniques has previously been investigated. These investigations indicated that, using dual-energy techniques, small microcalcifications could be extracted from the background breast morphology with sufficient signal to noise ratio (SNR) to be full visualized. The authors present the extension of a theoretical dual-energy model to incorporate practical considerations and then compare the results with experimentally derived data using a commercially available computed radiography system. In particular the extended model now takes into account the energy dependent detective quantum efficiency of a system. This is thought to be a major factor in reducing the efficiency of dual-energy mammography. The theoretical model predicts that dual-exposure dual-energy mammography, utilizing HRIII image plates, could not provide a detail SNR of five for calcifications smaller than 470 mu m. The experimental results verify this and indicate that dual-energy subtraction mammography, utilizing computed radiography, is currently not a viable technique for the detection of clinically significant microcalcifications. Further advances in X-ray image detector efficiency will be required if the full potential of this technique is to be achieved.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Determination of Crystal Structures
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET