Related Experiment Video
Updated: Aug 11, 2026

Intraluminal Drug Delivery to the Mouse Arteriovenous Fistula Endothelium
Published on: March 4, 2016
Venous oxygen embolism produced by injection of hydrogen peroxide into an enterocutaneous fistula
Philip M Jones1, Steven H Segal, Adrian W Gelb
1University of Western Ontario, Department of Anesthesia and Perioperative Medicine, London Health Sciences Centre, London, Ontario.
Abstract:
We report a venous oxygen embolism that occurred in a 66-yr-old man after 60 mL of 3% hydrogen peroxide was injected into a perianal fistula intraoperatively to locate its internal opening. The diagnosis was made after detecting hypoxemia, decreased end-tidal carbon dioxide tension, systemic hypotension, increased central venous pressure, and a new heart murmur. The patient recovered quickly and had no long-term sequelae. Oxygen embolism is a potentially fatal complication that can develop when hydrogen peroxide is used near venous spaces, and clinicians should be aware of the potential dangers when using this seemingly innocuous chemical.