Related Experiment Video
Updated: Aug 20, 2026

qPCR Is a Sensitive and Rapid Method for Detection of Cytomegaloviral DNA in Formalin-fixed, Paraffin-embedded Biopsy Tissue
Published on: July 9, 2014
Direct quantitative comparison of shell vial and conventional culture for detection of CMV viremia
R S Buller1, M Gaudreault-Keener, J Rossiter-Fornoff
1Department of Pediatrics, Washington University School of Medicine, St. Louis Children's Hospital, One Children's Place, St. Louis, MO 63110, USA.
Background:
Centrifugation shell vial (SV) and conventional tube culture (TC) are the most common methods for detecting cytomegalovirus (CMV) viremia. Studies have indicated that SV is more sensitive than TC but at least one report suggested that TC was more sensitive. Because CMV in the blood is primarily associated with infected leukocytes, the number of leukocytes inoculated into the different culture systems could affect the sensitivities of the two systems.
Objectives:
To compare the sensitivities of SV and TC for detection of CMV viremia by inoculating equal numbers of leukocytes into paired SV cultures and TC cultures.
Study Design:
Leukocytes from transplant recipients were isolated and counted. Equal numbers of leukocytes were then inoculated into each of two MRC-5 SV and into each of two MRC-5 TC. SV was considered positive when either one or both vials were positive, and TC was considered positive when either one or both tubes showed evidence of CMV cytopathic effect (CPE).
Results:
From a total of 434 specimens tested, 85 (19.6%) were positive by SV or TC. CMV was detected by SV in 75 (88%) of the positive specimens, compared to TC which was positive in 40 (47%) of the positive specimens.
Conclusions:
When equal numbers of leukocytes were inoculated into each system, SV had significantly greater sensitivity than TC for detecting CMV viremia. However, a small number of episodes of viremia were detected only by TC. Therefore, both methods should be used for maximum sensitivity.