Related Experiment Video
Updated: Jul 26, 2026

Measurement of Aggregate Cohesion by Tissue Surface Tensiometry
Published on: April 8, 2011
Humidity and aggregate content correction factors for air-coupled ultrasonic evaluation of concrete
J Berriman1, P Purnell, D A Hutchins
1School of Engineering, University of Warwick, Coventry CV4 7AL, UK.
Abstract:
This paper describes the use of non-contact ultrasound for the evaluation of concrete. Micromachined capacitance transducers are used to transmit ultrasonic longitudinal chirp signals through concrete samples using air as the coupling medium, and a pulse compression technique is then employed for measurement of time of flight through the sample. The effect on the ultrasonic wave speed of storing concrete samples, made with the same water/cement ratio, at different humidity levels is investigated. It is shown that there is a correlation between humidity and speed of sound, allowing a correction factor for humidity to be derived. A strong positive linear correlation between aggregate content and speed of sound was then observed; there was no obvious correlation between compressive strength and speed of sound. The results from the non-contact system are compared with that from a contact system, and conclusions drawn concerning coupling of energy into the samples.
More Related Videos
Related Concept Videos
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Moisture Content and Bulking of Aggregate
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
Unsoundness of Aggregate due to Volume Change
Factors Affecting Workability
Aggregate Cement Ratio
Measurement of Air Content in Concrete
The pressure method,...