Related Experiment Video
Updated: Aug 20, 2026

An Integrated Raman Spectroscopy and Mass Spectrometry Platform to Study Single-Cell Drug Uptake, Metabolism, and Effects
Published on: January 9, 2020
Development and validation of a direct, non-destructive quantitative method for medroxyprogesterone acetate in a
T R M De Beer1, G J Vergote, W R G Baeyens
1Laboratory of Drug Quality Control, Department of Pharmaceutical Analysis, Ghent University, Harelbekestraat 72, B-9000 Ghent, Belgium.
Abstract:
A simple linear regression method was developed and statistically validated for the direct and non-destructive quantitative analysis--without sample preparation--of the active pharmaceutical ingredient (API) medroxyprogesterone acetate (MPA) in an aqueous pharmaceutical suspension (150 mg in 1.0 ml) using FT-Raman spectroscopy. The linear regression was modelled by plotting the highest peak intensity of the vector normalized spectral band between 1630 and 1590 cm-1 against different MPA standard suspension concentrations. At this band, no spectral interferences from additives in the suspension are observed. The validated model was used for the quantification of a commercial suspension (150 mg in 1.0 ml) of the commercialized preparations. The same standards and samples were used, respectively, for the development and validation of a simple linear regression model and for the quantitative determination by means of HPLC-with sample preparation-as described for the related substances of MPA in the Ph. Eur. IV. The quantification results obtained by the FT-Raman method corresponded with the claimed label concentration (150.01+/-0.96 mg/ml (n=6)). Applying the HPLC method, however, a systematic error was observed (157.77+/-0.94 mg/ml (n=6)). The direct FT-Raman method hence appears the most reliable for the quantification of the MPA component in suspension, compared to the HPLC method that requires sample preparation. The latter method provides a systematic error because the exact volume or density of a suspension sample is unknown. A precise isolation of fixed volumes from a suspension is rather unfeasible because of the continuous sagging of the suspended particles and their sticking to the used materials in the isolation process.
More Related Videos
09:59Coherent anti-Stokes Raman Scattering (CARS) Microscopy Visualizes Pharmaceutical Tablets During Dissolution
Published on: July 4, 2014
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017