[Intracranial artifact un magnetic resonance caused by embolization of microscopic metallic fragment]

O Gorriño1, L Oleaga, R de la Fuente

  • 1Servicio de Radiodiagnóstico, Hospital de Basurto, Bilbao. olagorri@hbas.osakidetza.net

Insights

This case study highlights a metallic artifact on magnetic resonance imaging (MRI) in a patient with stroke symptoms. The artifact was linked to a metallic fragment embolization during previous cardiac surgery.

Area of Science:

  • Medical Imaging
  • Neurology
  • Cardiology

Background:

  • Magnetic resonance imaging (MRI) artifacts are common findings with various causes.
  • Understanding artifact origins is crucial for accurate diagnosis and patient management.

Observation:

  • A 72-year-old male presented with left lower limb weakness.
  • MRI revealed an acute right posterior cerebral artery infarction.
  • A distinct metallic artifact with central signal void and high signal rim was noted in the right frontal lobe.

Findings:

  • The metallic artifact was attributed to a small metallic fragment.
  • The fragment was likely embolized during aortic valve replacement surgery 12 years prior.

Implications:

  • This case underscores the importance of considering prior surgical interventions when interpreting MRI findings.
  • Identifying metallic artifacts aids in differentiating them from actual pathology, improving diagnostic accuracy.