Pseudo-rupture of Extensor Pollicis Longus following Kischner wire fixation of distal radius fractures
Mark R Harrison1, Steven Hamilton, Alan J Johnstone
1Aberdeen Royal Infirmary, Aberdeen, Scotland.
Abstract:
We report two cases of extensor pollicis longus tendon tethering following K-wire insertion to treat unstable distal radius fractures, an unusual complication. In both cases, extensor pollicis longus function returned with conservative management. The structures considered "at risk" during K-wire insertion are described, and the common complications are discussed. Operative approaches to minimise soft tissue damage during K-wire insertion are reviewed. This case report is the first to demonstrate the potential for ultrasound scanning to aid in the diagnosis of extensor pollicis longus tethering.
More Related Videos
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
11:21Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Related Concept Videos
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi radialis,...