Determination of transverse relaxation rate for estimating iron deposits in central nervous system
Tachio Hikita1, Kazuo Abe, Saburo Sakoda
1Department of Neurology, D-4, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan. hikitati@neurol.med.osaka-u.ac.jp
Abstract:
To determine the amount of iron deposits in the basal ganglia, we examined 13 healthy volunteers with a 1.5 T MRI system using three transverse relaxation rates measured with two sequences. The transverse relaxation rates comprise the reversible contribution (R2') and irreversible contribution (R2) to a phase-reversal 180 degrees -pulse sequence. The transverse relaxation rates with the estimated iron indicated that both R2 and R2' had a robust relationship with brain iron level as determined from published post mortem data. This was the case only when the analyses are limited to the subcortical gray matter regions, however. R2' was affected by macroscopic magnetic field inhomogeneity arising from the skull bases, so that it was less robust for estimating the amount of iron deposits in the basal ganglia.
Related Concept Videos
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers energy to a nearby...