Related Experiment Video
Updated: Aug 20, 2026

Open Source High Content Analysis Utilizing Automated Fluorescence Lifetime Imaging Microscopy
Published on: January 18, 2017
Applying open-path FTIR with computed tomography to evaluate personal exposures. Part 2: experimental studies
Chang-Fu Wu1, Michael G Yost, Ram A Hashmonay
1Department of Environmental and Occupational Health Sciences, Box 357234, University of Washington, Seattle, WA 98195, USA.
Abstract:
This paper presents the experimental evaluation results of using computed tomography coupled with OP-FTIR (CT-FTIR) measurement to estimate personal exposures. Experimental data were collected inside a ventilation chamber with a remote controlled robot as a surrogate for a real human. While the robot moved inside the chamber, a tracer gas (carbon monoxide) was released from a line source. A personal sampling device measured the true exposure on the robot. The estimated personal exposures were calculated from both the area sampling array data and the CT-FTIR measurements along with the information about the robot's locations in real time. The location information was obtained by applying image analysis on recorded digital videotapes. The average slopes of the regression lines between the true and estimated exposures was 0.76 with 1 included in the 95% confidence interval. The concordance correlation factor (CCF) between the true and the CT-FTIR estimated exposures was 0.52, which was similar to the findings from previous simulation studies. Kriging the area sampling array data with an exponential algorithm instead of a liner algorithm improved the CCF value from 0.60 to 0.75. This suggests that using a different basis function for the SBFM algorithm might improve the performance of our estimation approach. Based on the sensitivity and specificity analysis of the experimental data, we demonstrated that this approach is suitable as a warning system.
More Related Videos
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET