Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Cerebrospinal fluid pulse pressure method: a possible substitute for the examination of B waves
Niklas Lenfeldt1, Nina Andersson, Aina Agren-Wilsson
1Department of Clinical Neuroscience, Umeå University Hospital, University of Umeå, Sweden. niklas.lenfeldt@neuro.umu.se
Object:
The appearance of numerous B waves during intracranial pressure (ICP) registration in patients with idiopathic adult hydrocephalus syndrome (IAHS) is considered to predict good outcome after shunt surgery. The aim of this study was to describe which physical parameters of the cerebrospinal fluid (CSF) system B-waves reflect and to find a method that could replace long-term B-wave analysis.
Methods:
Ten patients with IAHS were subjected to long-term registration of ICP and a lumbar constant-pressure infusion test. The B-wave presence, CSF outflow resistance (R(out)), and relative pulse pressure coefficient (RPPC) were assessed using computerized analysis. The RPPC was introduced as a parameter reflecting the joint effect of elastance and pulsatory volume changes on ICP and was determined by relating ICP pulse amplitudes to mean ICP.
Conclusions:
The B-wave presence on ICP registration correlates strongly with RPPC (r = 0.91, p < 0.001, 10 patients) but not with CSF R(out). This correlation indicates that B waves-like RPPC-primarily reflect the ability of the CSF system to reallocate and store liquid rather than absorb it. The RPPC-assessing lumbar short-term CSF pulse pressure method could replace the intracranial long-term B-wave analysis.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical indicator...