Effects of a suppressor tone on distortion product otoacoustic emissions fine structure: why a universal suppressor

Sumitrajit Dhar1, Lauren A Shaffer

  • 1Department of Speech and Hearing Sciences, Indiana University, Bloomington, Indiana 47405, USA.

Ear and Hearing
|December 18, 2004
PubMed
Abstract

Related Concept Videos

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Concept of Resonance and its Characteristics01:19

Concept of Resonance and its Characteristics

If a driven oscillator needs to resonate at a specific frequency, then very light damping is required. An example of light damping includes playing piano strings and many other musical instruments. Conversely, to achieve small-amplitude oscillations as in a car's suspension system, heavy damping is required. Heavy damping reduces the amplitude, but the tradeoff is that the system responds at more frequencies. Speed bumps and gravel roads prove that even a car's suspension system is not immune...
Characteristics of Practical Op Amps01:16

Characteristics of Practical Op Amps

A difference amplifier, a crucial component in numerous electronic devices, ideally amplifies only the difference-mode signal, which is the difference between two input signals. However, in practical circuits, the output voltage depends on both the differential gain and the common-mode gain.
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...