Detection of respiratory sounds at the external ear
Gary A Pressler1, Jeffrey P Mansfield, Hans Pasterkamp
1Department of Biomedical Engineering, Purdue University, West Lafayette, IN 47907-2022, USA. pressleg@purdue.edu
Abstract:
Several clinical and ambulatory settings necessitate respiratory monitoring without a mouthpiece or facemask. Several studies have demonstrated the utility of breathing sound measurements performed on the chest or neck to detect airflow. However, there are limitations to skin surface measurements, including susceptibility to external noise and transducer motion. Thus, this two-part study investigated a novel location for breathing sound measurements: the external ear. The first study investigated characteristics of sound transmission from the oropharynx to the external ear in 19 adults (nine males). Broadband noise was directed into the oropharynx through a tube and mouthpiece and measured indirectly via an accelerometer affixed to the cheek. Resultant transmission to the external ear was measured with a microphone inserted into an earplug that provided acoustic isolation from ambient noise. Near-unity coherence estimates (> 0.9) between the sounds recorded at the external ear and the oropharynx were observed up to approximately 800 Hz, indicating a low-frequency region of preferred transmission. In the second study, each of 20 subjects (nine males) breathed through a pneumotachograph at targeted shallow (3.0 mL/s/kg) and tidal (7.5 mL/s/kg) flows normalized to body mass, and the resulting sounds were recorded at the external ear. Recordings during breath hold measured background noise. Shallow and tidal expiratory flows, respectively, produced signal-plus-noise-to-noise [(S + N)/N] ratios of 6.7 +/- 4.1 dB and 14.0 +/- 5.3 dB (mean +/- standard deviation) across all subjects between 150 and 300 Hz. Concurrent inspiration demonstrated (S + N)/N ratios of 6.6 +/- 3.9 dB and 14.9 +/- 6.3 dB. Thus, the external ear shows promise as an anatomic site to detect and monitor breathing in a relatively noninvasive and unobtrusive manner.
Related Concept Videos
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...