Related Experiment Video
Updated: Jul 27, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
[First line application of a modified dilatational tracheostomy in the intensive care]
J M Proske1, J C Rückert, H Zuckermann-Becker
1Abteilung für Allgemein-, Viszeral-, Gefäss- und Thoraxchirurgie, Charité Campus Mitte, Humboldt-Universität Berlin. proske@altern.org
Background:
Despite the growing clinical use of the percutaneous dilatational tracheostomy data concerning their first line application are still lacking.
Methods:
Retrospective analysis of the intra- and postinterventional morbidity of a modified dilatational tracheostomy in a surgical intensive care unit of a German university hospital over a 2-year period.
Results:
A total of 107 elective dilatational tracheostomies were performed in 105 patients. There were no intraoperative complications. 2 accidental decannulations occurred in the postoperative period. One conventional tracheostomy had to be performed secondary. Stoma side bleeding or clinical relevant infection had not been observed. After definite decannulation wound closure was spontaneous in all patients.
Conclusions:
The first line application of the dilatational tracheostomy has a low morbidity.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques