Background:
Abdominal compartment syndrome can develop within 12 hours of intensive care unit (ICU) admission in high-risk (shock/trauma, burn, pancreatitis, postabdominal aortic surgery) patients. The current standard of intra-abdominal pressure (IAP) measurement via the urinary catheter is labor intensive, and its intermittent nature could prevent timely recognition of significant changes in IAP. We propose that continuous IAP (CIAP) can be accurately measured via the irrigation port of a three-way catheter and has good agreement with the standard intermittent IAP (IIAP).
Methods:
CIAP was prospectively validated by comparing it with IIAP measurement in general surgical and trauma patients admitted to the ICU with a three-way urinary catheter. CIAP was measured via the irrigation port of the three-way catheter transduced to the bedside monitor as a continuous trace without intermittent clamping of the catheter. The standard IIAP measurements were performed via the urine drainage port after clamping the catheter and filling the bladder with 50 mL of 0.9% saline. Each patient had three separate paired measurements performed in standardized manner to compare CIAP with IIAP. Patients' demographics, injury severity, type of surgery, body mass index (BMI), and the paired individual IAP measurements were recorded. The paired measurements were compared using the Bland-Altman (B-A) method for comparing a new clinical measurement with an established one. Data are presented as mean +/- standard error of the mean.
Results:
During a 6-month period (ending in July 2003), 25 patients were investigated. The mean age was 61.5 +/- 4 years, 66% were men, and BMI was 29.2 +/- 2 kg/m(2). Six patients had vascular surgical, four elective and three urgent general surgical interventions. There were 12 trauma patients with ISS of 23 +/- 2. The CIAP was 14.2 +/- 0.66 (range 2 to 24) mm Hg, and the IIAP was 14.0 +/- 0.68 (range 3 to 24) mm Hg. Seventy-five percent of the measured pairs were exactly the same; in 21%, there was 1 mm Hg difference and in 4% 2 mm Hg. There was no measurement difference greater than 2 mm Hg. The mean difference between the CIAP and IIAP was 0.019 +/- 0.05 mmHg. The B-A statistics revealed that the difference between the means of measurements in each individual patient was between +/-1.96 SD (95% confidence intervals). The B-A scatter plot did not follow any patterns of typical systematic bias.
Conclusion:
CIAP measurement with a three-way urinary catheter is a simple and accurate method for monitoring IAP. It has an excellent agreement with the IIAP over wide pressure ranges and should replace the current labor-intensive intermittent technique.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of the Abdomen III: Palpation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...