Related Experiment Video
Updated: Aug 20, 2026

MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
Published on: January 16, 2021
Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications
M Alfonsetti1, V Clementi, S Iotti
1INFM and Dipartimento di Scienze e Tecnologie Biomediche, Università dell'Aquila, Via Vetoio, 67100 L'Aquila, Italy. maria.alfonsetti@univaq.it
Abstract:
Clinical MRI/MRS applications require radio frequency (RF) surface coils positioned at an arbitrary angle alpha with respect to B(0). In these experimental conditions the standard circular loop (CL) coil, producing an axial RF field, shows a large signal loss in the central region of interest (ROI). We demonstrate that transverse-field figure-of-eight (FO8) RF surface coils design are not subject to the same amount of signal loss in the central ROI as loop coils when their orientations are changed. The 1.5-T CL and FO8 prototypes (diameter = 10 cm) were built on Plexiglas using copper strips (width = 4 mm, thickness = 100 mum). The two linear elements of the FO8 coil were 1 cm apart. Axial spoiled gradient echo (SPGR) images of a phantom containing doped water were acquired with the coil plane at alpha=0 degrees , 45 degrees , and 90 degrees . As alpha increases, the CL images show, in the central ROI, a signal that decreases from a maximum value to zero. Whereas the FO8 images show, in the same ROI, a signal that varies little from the maximum value (20%). Optimized FO8 coils can be oriented with the coil plane positioned along any direction with respect to B(0) without significant signal loss. Transverse RF coil design should be useful for clinical MRS studies and also for parallel imaging techniques where versatile RF coils disposed along arbitrary directions are required.
Related Concept Videos
Magnetic Resonance Imaging
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Of A Current Loop
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...