Related Experiment Video
Updated: Aug 20, 2026

Rendering SiO2/Si Surfaces Omniphobic by Carving Gas-Entrapping Microtextures Comprising Reentrant and Doubly Reentrant Cavities or Pillars
Published on: February 11, 2020
Characterization of the acidity of residual silanol groups in microparticulate and monolithic reversed-phase columns
José Manuel Herrero-Martínez1, Alberto Méndez, Elisabeth Bosch
1Departament de Química Analítica, Universitat de Barcelona, Diagonal 647, E-08028 Barcelona, Spain.
Abstract:
The residual silanol acidity and activity of several microparticulate and monolithic C18 columns has been measured from the retention of LiNO3 in the columns with a methanol/buffer (1 mM in Na+) (60:40 v/v) mobile phase buffered to different pH values. For Luna C18 (2) and LiChrospher RP-18 columns, at least two different types of silanols with different acidity for each packing, were observed. Purospher RP-18e and Chromolith RP-18e packings present evidence of some active silanols only at pH values close to their basic pH stability limit or higher. The results obtained have been compared with those obtained previously for Resolve C18, Resolve Silica, Symmetry C18, Symmetry Silica, XTerra MSC18 and Underivatized XTerra. A modification of an equation previously proposed has been applied to all columns studied and the results obtained have been used to classify the columns according to their silanol acidity and activity. The method allows the prediction of the extent of the silanol activity of the columns studied at a particular mobile phase pH.
More Related Videos
09:37Imine Metathesis by Silica-Supported Catalysts Using the Methodology of Surface Organometallic Chemistry
Published on: October 18, 2019
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion Exchange
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Analyte Adsorption and Distribution
Composition of Polyprotic Acid Solutions as a Function of pH
A graph with the alpha values is plotted against the volume of base added during titration. Here, a...