Related Experiment Video
Updated: Aug 20, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Utility of three dimension fast asymmetric spin-echo (3D-FASE) sequences in MR sialographic sequences: model and
1Department of Dental Radiology, Kyushu Dental College, Kokurakita-ku, Kitakyushu, Japan. ra-mori@kyu-dent.ac.jp
Objectives:
To evaluate the utility of 3D-FASE for the visualization of salivary gland ducts for use in MR sialographic sequences.
Methods:
We compared MR sialographic images and virtual endoscopic views from 3D-FASE with those from three kinds of sequences described by previous reports in a 3D parotid gland duct model and volunteer. The four sequences were two-dimension fast spin-echo (2D-FSE), three-dimension fast spin-echo (3D-FSE), two-dimension fast asymmetric spin-echo (2D-FASE), and three-dimension fast asymmetric spin-echo (3D-FASE).
Results:
In the 3D parotid gland duct model, image visibility on visual score was clearest with 3D-FSE, followed by 3D-FASE (P = 0.028). In the volunteers, the visualization of images improved in the following order: 3D-FASE > 3D-FSE > 2D-FSE > 2D-FASE.
Conclusions:
The technique of 3D-FASE sequencing is more suitable and useful for MR sialography with an appropriate acquisition time.