Related Experiment Video
Updated: Aug 20, 2026

Genotyping of Staphylococcus aureus by Ribosomal Spacer PCR (RS-PCR)
Published on: November 4, 2016
Evaluation of six commercial identification kits for the identification of Staphylococcus aureus isolated from bovine
M Zschöck1, A Nesseler, I Sudarwanto
1Public Investigation Office Hesse, Department of Veterinary Medicine, Giessen, Germany. m.zschoeck@suah.hessen.de
Aims:
Comparison of six commercially available in human medicine well-established slide agglutination systems for the identification of Staphylococcus aureus.
Methods And Results:
Slide agglutination tests were compared with the conventional tube coagulase test, biochemical identification and with the molecular identification by polymerase chain reaction (PCR) amplification of species-specific parts of the gene encoding the 23S RNA. Systems evaluated included Masta-Staph (Mast Diagnostics), Staphylase-Test (Oxoid), Staphytect-Plus (Oxoid), Staphyloslide Latex (Becton Dickinson), Slidex Staph Plus (bioMerieux) and Dry Spot Staphytect Plus (Oxoid). A total of 141 staphylococcal strains isolated from cases of bovine mastitis including 90 S. aureus, 14 Staphylococcus epidermidis, 10 Staphylococcus warneri, 13 Staphylococcus xylosus, 11 Staphylococcus haemolyticus and three other coagulase-negative staphylococci were tested with each method. Staphylococcus aureus strains were selected by macrorestriction analysis with pulsed field gel electrophoresis (PFGE). Only genetically unrelated strains were included in the study. The sensitivities and specificities of the test were as follows: Masta-Staph 86.7 and 90.1%, Staphylase-Test 78.4 and 85.1%, Staphytect-Plus 81.1 and 86.5%, Staphyloslide Latex 77.8 and 84.4%, Slidex Staph Plus 77.8 and 84.4%, Dry Spot Staphytect Plus 75.6 and 83.0%.
Conclusions:
The results of this evaluation suggest that the six slide agglutination methods tested can provide rapid identification of S. aureus also from bovine mastitis. The sensitivity and specificity seems to be less than those reported from human S. aureus isolates.
Significance And Impact Of The Study:
This is one of the first comparative reported investigations about the applicability of different commercially available slide agglutination tests for the detection of S. aureus from bovine mastitis using PFGE selected clinical isolates.
More Related Videos
09:07Direct Microbial Identification using An Automated Microbial Identification System to Facilitate the EUCAST RAST Method Without Mass Spectrometry
Published on: May 24, 2024
09:31Evaluation of Microbial Safety of Dairies using Bacterial Proteomic Profiling via MALDI Approach
Published on: October 7, 2025
Related Concept Videos
Automated Microbial Diagnostics
Methods of Classification and Identification
Rapid Identification of Pathogens
Differential Staining Technique