Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Time-domain semi-parametric estimation based on a metabolite basis set.

H Ratiney1, M Sdika, Y Coenradie

  • 1Laboratoire de RMN, CNRS UMR 5012, Université Claude Bernard Lyon I-CPE, Villeurbanne, France.

NMR in Biomedicine
|January 22, 2005
PubMed
Summary

A new algorithm, Quantitation based on Semi-Parametric Quantum Estimation (QUEST), accurately quantifies metabolic signals from noisy data. It effectively handles background noise, improving precision in various magnetic resonance spectroscopy applications.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An Explicit Estimated Baseline Model for Robust Estimation of Fluorophores Using Multiple-Wavelength Excitation Fluorescence Spectroscopy.

IEEE transactions on bio-medical engineering·2023
Same author

Framework for integrated MRI average of the spinal cord white and gray matter: the MNI-Poly-AMU template.

NeuroImage·2014
Same author

3D localized 2D ultrafast J-resolved magnetic resonance spectroscopy: in vitro study on a 7 T imaging system.

Journal of magnetic resonance (San Diego, Calif. : 1997)·2012
Same author

Changes in mouse brain metabolism following a convulsive dose of soman: a proton HRMAS NMR study.

Toxicology·2009
Same author

Quantitation with QUEST of brain HRMAS-NMR signals: application to metabolic disorders in experimental epileptic seizures.

Magnetic resonance in medicine·2008
Same author

Semi-parametric estimation in magnetic resonance spectroscopy: automation of the disentanglement procedure.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2007

Area of Science:

  • Magnetic Resonance Spectroscopy (MRS)
  • Metabolomics
  • Biophysical Chemistry

Background:

  • Quantifying low signal-to-noise ratio (SNR) in vivo MRS data is challenging.
  • Background signals from macromolecules and lipids often hinder accurate metabolite quantitation.
  • Existing methods may introduce bias or variance in quantitation.

Purpose of the Study:

  • To introduce and evaluate a novel time-domain quantitation algorithm, QUEST.
  • To develop and compare semi-parametric approaches for handling background signals.
  • To assess the performance and precision of the QUEST algorithm in various MRS scenarios.

Main Methods:

  • Developed a nonlinear least-squares algorithm (QUEST) using quantum-mechanically simulated or in vitro measured metabolite signals.

Related Experiment Videos

  • Implemented three novel semi-parametric methods to address background signal interference.
  • Utilized Monte Carlo simulations to evaluate method performance and bias-variance trade-offs.
  • Calculated Cramér-Rao lower bounds to account for background uncertainty.
  • Main Results:

    • QUEST algorithm demonstrated effective quantitation of low-SNR MRS data.
    • The proposed semi-parametric methods successfully managed background signals.
    • Extensive Monte Carlo studies validated the performance and precision of the QUEST algorithm.
    • Demonstrated successful quantitation of 1H and 31P MRS data from in vitro, in vivo, and human brain samples.

    Conclusions:

    • QUEST is a fast and accurate algorithm for time-domain MRS quantitation.
    • The developed methods offer improved handling of background signals, enhancing quantitation precision.
    • QUEST provides valuable insights into quantitation accuracy and is applicable to diverse MRS datasets.