Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
X-ray absorption near-edge structure analysis of arsenic species for application to biological environmental samples
Paula G Smith1, Iris Koch, Robert A Gordon
1Biology Department, Queen's University, Kingston, Ontario, Canada K7L3N6.
Abstract:
Arsenic is an element that is ubiquitous in the environment and is known to form compounds with toxic, even carcinogenic properties. Arsenic toxicity is a function of its chemical form (species). Identification of arsenic species is necessary to accurately determine the transformation and fate of arsenicals as well as the actual risk posed by arsenic contamination. We report X-ray absorption near-edge structure (XANES) measurements of 16 biologically important arsenic compounds. Solid and aqueous standards were studied for differences in XANES spectral features, white line positions, stability during exposure to the beam, and stability between two beam exposures separated by 48 h. Samples containing As(III) (11870.0-11871.7+/-0.5 eV) and As(V) (11872.6-11875.3+/-0.5 eV) were easily distinguished by white line energies and could be further subdivided into a total of seven groups. Valuable examples include As(III)-sulfur compounds (11870.0+/-0.5 eV), arsenobetaine and arsenocholine (11872.6+/-0.5 eV), and a dimethyl arsinyl riboside (11873.3+/-0.5 eV). A growing number of environmental and biological studies use X-ray absorption spectroscopy (XAS) results to complement their more traditional analyses. Results provided here are intended to help make XAS more accessible to new users interested in the study of arsenic in the environment.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Emission Spectroscopy: Overview
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Atomic Emission Spectroscopy: Interference
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...