Related Experiment Video
Updated: May 27, 2026

Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
Chronic obstructive pulmonary disease: thin-section CT measurement of airway wall thickness and lung attenuation
Ilaria Orlandi1, Chiara Moroni, Gianna Camiciottoli
1Radiodiagnostic Section, Department of Clinical Physiopathology, University of Florence, Viale Morgagni 85, Florence 50134, Italy.
Purpose:
To prospectively evaluate airway wall thickness and lung attenuation at spirometrically gated thin-section computed tomography (CT) in patients with chronic obstructive pulmonary disease (COPD) and to correlate gated CT findings with pulmonary function test (PFT) results.
Materials And Methods:
The ethical committee approved the study, and all patients gave informed consent. Forty-two consecutive patients with COPD (20 with and 22 without chronic bronchitis [CB]) underwent gated thin-section CT and PFTs on the same day. The percentage wall area (PWA) and the thickness-to-diameter ratio (TDR) for all depicted bronchi that were round and larger than 2 mm in diameter, the mean lung attenuation (MLA), and the pixel index (PI) at -950 HU were determined. The reproducibility of the airway measurements was preliminarily tested by performing a five-trial examination in a patient with COPD and in a control patient. Differences in airway and lung attenuation measurements between the patients with and those without CB were evaluated at Mann-Whitney U testing. Simple and multiple regression analyses were used to assess the correlation between thin-section CT and PFT measurements.
Results:
The mean intraoperator coefficient of variation for airway measurements was 7.8% (range, 3.8%-13.4%). An average of nine bronchi per patient were assessed. Patients with CB had significantly higher PWAs, TDRs, and MLAs and significantly lower PIs than patients without CB (P < .05 for all values). The combination of PWA, TDR, and PWA normalized to body weight correlated significantly (P < .05) with the forced expiratory volume in 1 second-to-slow vital capacity ratio and the diffusing capacity of the lung for carbon monoxide in patients with but not in patients without CB. PFT results correlated better with MLA and PI in patients without CB.
Conclusion:
Bronchial wall measurements differ between patients who have COPD with CB and those who have COPD without CB. The correlation between airway dimensions and indexes of airway obstruction in patients with COPD and CB indicates that the bronchial tree is the site of anatomic-functional alterations in this patient group.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
03:38Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
Published on: June 20, 2025
Related Concept Videos
Chronic Obstructive Pulmonary Disease-I: Introduction
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease II: Emphysema
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Chronic Obstructive Pulmonary Disease IV: Clinical Manifestations