Ulrich A Baumann1, Claudia Marquis, Christoforos Stoupis
1Department of Internal Medicine, Regional Hospital, 3110 Münsingen, Switzerland.
Introduction:
Increasing blood volume and cardiac output is one of the most commonly needed intervention in the primary care of traumatized and severely ill patients. Although cardiac filling pressures have severe limitations in assessing the preload, central venous pressure (CVP) is the invasive measure most frequently used in clinical practice for the assessment of volume status and cardiac preload. We combined ultrasound and tissue pressure measurement for non-invasive jugular and brachial venous pressure estimation.
Materials And Methods:
CVP was measured invasively and non-invasively using the new technique in 32 critically ill patients. In six volunteers, increasing PEEP was used for the assessment of changes in non-invasive CVP.
Results:
Non-invasive CVP increased linearly with increasing PEEP, independent of the investigator. Median (range) coefficient of variation (CV) for five consecutive measurements performed by three investigators in volunteers was 15% (6-31%), 14% (4-31%), and 21% (8-42%). Absolute differences between the average non-invasive CVP between investigators was 1.7 cm H2O (0.4-6.6 cm H2O), and the inter-examiner CVP was high (182%, 40-415%). In patients, invasive CVP was 10 mmHg (5-18 mmHg), and the corresponding non-invasive venous pressures were 8 mmHg (3-14 mmHg, basilic vein, p<0.01) and 6 mmHg (3-13 mmHg, jugular vein, p<0.01). The coefficients of variation were 4% (<1%-64%, invasive CVP), 22% (5%-51%, non-invasive basilic vein pressure), and 17% (7%-34%, non-invasive jugular vein pressure).
Conclusion:
Ultrasound-based, non-invasive measurement of venous pressure provides a relatively easy method rapid estimation of changes in CVP, although absolute values may differ substantially from invasive CVP and between different investigators.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement