A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
A new endocardial "over-the-wire" or stylet-driven left ventricular lead: first clinical experience
Sue Ellery1, Vince Paul, Guenther Prenner
1St Peter's Hospital, Chertsey, Surrey, United Kingdom. sue.ellery@asph.nhs.uk
Abstract:
Transvenous left ventricular (LV) leads are primarily inserted "over-the-wire" (OTW). However, a stylet-driven (SD) approach may be a helpful alternative. A new polyurethane-coated, unipolar LV lead can be placed either by a stylet or a guide wire, which can be inserted into the lead body from both ends. The multicenter OVID study evaluates the clinical performance of this new steroid- and nonsteroid eluting lead. The primary endpoint is the LV lead implant success rate after identification of the coronary sinus (CS). Secondary endpoints include complication rate, short- and long-term lead characteristics, overall procedure and LV lead placement duration, total fluoroscopy time, and lead handling characteristics ratings. To date, 96 patients with heart failure (68 +/- 9 years old, 76% men) are enrolled. The CS was identified in 95 patients and, in 85 (88.5%), the LV lead was successfully implanted. The final lead positioning was lateral in 41%, posterolateral in 35%, anterolateral in 18%, and great cardiac vein in 6% of patients. In 70%, the 85 successful implantations, both stylet-driven and guide-wire techniques were used, a stylet only was used in 22%, and a guide wire only in 8%. Mean overall duration of 85 successful procedures was 112 +/- 40 minutes, total fluoroscopy time 28 +/- 15 minutes, and the duration of LV lead placement was 35 +/- 29 minutes. During a 3-month follow-up, the loss of LV capture occurred in three and phrenic nerve stimulation in six patients. The mean long-term pacing threshold is 0.8 V/0.5 ms and pacing impedance is 550 Omega. The OVID data suggest that these new leads are safe and effective. The choice of both OTW and SD techniques during lead implantation offers greater procedural flexibility.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Cardiac Catheterization I: Pre-Procedure Overview