A simple and reliable predictor for an adequate laryngeal view with rigid endoscopic laryngoscopy
Christopher Low1, Pam Young, Christopher J Webb
1ENT Department, Royal Liverpool University Hospital, United Kingdom. c.low1@btinternet.com
Objectives:
It is sometimes impossible to obtain an adequate laryngeal view during rigid endoscopic laryngoscopy. This may be due to a high tongue base. Our study seeks to determine a correlation between tongue base level and the adequacy of laryngeal view obtained with a 70-degree rigid endoscope.
Study Design And Setting:
Over a period of 4 months, patients from a voice clinic were gathered and categorized into class I to III according to Mallampati et al (1985). Rigid laryngo-videostroboscopy was conducted to assess the larynx and the adequacy of the view was recorded.
Results:
74 patients were recruited. The number of adequate views were: class I = 18/20 (90%); class II = 20/33 (60.6%); class III = 7/21 (33.3%). chi 2 analysis demonstrated significance trend in all 3 classes.
Conclusion:
The level of the tongue base correlated well with the adequacy of laryngeal view obtained from a 70-degree rigid endoscope. This can be used to predict the success of obtaining adequate views during rigid laryngoscopy.