Extraction and Quantification of Soluble, Radiolabeled Inositol Polyphosphates from Different Plant Species using SAX-HPLC
Published on: June 26, 2020
HPLC with inductively coupled plasma optical emission spectrometric detection for the analysis of inositol phosphates
Rosa Amaro1, Andrés Escalona, Miguel Murillo
1Centro de Química Analítica, Escuela de Química, Facultad de Ciencias, Universidad Central de Venezuela, Apartado de Correos 47102, Caracas 1041A, Venezuela.
Abstract:
The use of inductively coupled plasma optimal emission spectroscopy as a detector for the high-performance liquid chromatographic analysis of inositol phosphates is studied. It is found that separation of different inositol phosphates with a mobile phase consisting of tetraethylammonium (0.14%, w/v), methanol (5%, v/v), and formic acid (0.18%, w/v) may be obtained on a PRP-1 column with an analysis time of 18 min. In addition, high specificity and sensitivity of the detection system used permits detection of the inositol phosphates from bi- to hexaphosphate free from interference of other chromatographic peaks, which could be from the sample or mobile phase. Additionally, it is possible to use less sample because of the high sensitivity of the detection system.
More Related Videos
09:22Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
Published on: August 13, 2021
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Gas Chromatography: Types of Detectors-II
Phosphoinositides and PIPs
Different phosphoinositides are synthesized and recruited on the cytosolic face of the plasma membrane. The localization of specific phosphoinositides concentrated in separate membrane...