Related Experiment Video
Updated: Aug 19, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
[Determination of hydromorphone in Beagle dogs plasma by liquid chromatography-tandem mass spectrometry]
Xiao-Yan Li1, Xiao-Yan Chen, Qing-Ying Yan
1Laboratory of Drug Metabolism and Pharmacokinetics, Shenyang Pharmaceutical University, Shenyang 110016, China.
Aim:
To establish a LC/MS/MS method for determination of hydromorphone (HYD) in Beagle dog plasma.
Methods:
After incubation with beta-glucuronidase for 16 h, an aliquot of 0.1 mL plasma was treated by liquid-liquid extraction. The analytes of interest were separated on a Zorbax SB C8 column with the mobile phase consisting of methanol-water- formic acid (65: 35: 1). Atmospheric pressure chemical ionization source of MS was applied and operated in positive ion mode.
Results:
The linear calibration curve was obtained in the concentration range of 0.80 - 200.0 microg x L(-1). The lower limit of quantification was 0.80 microg x L(-1). The inter-day and intra-day precision (RSD) was below 6.0%, and the accuracy (RE) was within 1% calculated from QC samples. The method was used to determine the pharmacokinetic parameters of HYD after a single oral administration of 4 mg HYD sustained release tablets to Beagle dogs.
Conclusion:
The method was proved to be specific, sensitive, and suitable for the pharmacokinetic study of HYD sustained release formulation.