Related Experiment Video
Updated: Aug 19, 2026

Multi-analyte Biochip (MAB) Based on All-solid-state Ion-selective Electrodes (ASSISE) for Physiological Research
Published on: April 18, 2013
Determination of medecamycin by adsorptive stripping voltammetry with an activated electrode
Nian Bing Li1, Hong Qun Luo, Guo Nan Chen
1School of Chemistry and Chemical Engineering, Southwest China Normal University, Chongqing 400715, P.R. China. linb@swnu.edu.cn
Abstract:
The adsorptive and electrochemical behaviors of medecamycin were investigated on a glassy carbon electrode (GCE) pretreated by anodic oxidation at +1.8 V for 5 min in 0.025 mol l(-1) NH(3)-NH(4)Cl (pH 8.6) solution. An adsorptive stripping voltammetric method for the determination of medecamycin at the pretreated glassy carbon electrode has been developed. Medecamycin was accumulated in NH(3)-NH(4)Cl buffer (pH 9.0) at a potential of -0.7 V (vs. saturated calomel electrode (SCE)) for a certain time, and then determined by second-order differential anodic stripping voltammetry. The second-order differential anodic stripping peak current at +0.72 V was proportional to the concentration of medecamycin in the range 2.0 microg ml(-1) to 50.0 microg ml(-1). The detection limit (three times the signal-to-noise) was 1.0 microg ml(-1) and the relative standard deviation of the results was 3.28% for eight successive determinations of 10.0 microg ml(-1) medecamycin. This method has been applied to the direct determination of medecamycin in commercial tablets and spiked urine samples with satisfactory results.
More Related Videos
12:11ELIME (Enzyme Linked Immuno Magnetic Electrochemical) Method for Mycotoxin Detection
Published on: October 23, 2009
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetric Techniques: Cyclic Voltammetry
Electrodeposition
Electrodeposition can...