Extracting the Cochlea from a Human Temporal Bone: A Cadaveric Protocol
Published on: August 18, 2023
CT of the normal temporal bone: comparison of multi- and single-detector row CT
Lorenz Jäger1, Harald Bonell, Martin Liebl
1Institute of Clinical Radiology, University of Munich, Klinikum Grosshadern, Marchioninistrasse 15, 81366 Munich, Germany. jaeger@med.uni-muenchen.de
Purpose:
To evaluate multi- and single-detector row computed tomographic (CT) depiction of anatomic landmarks of temporal bone.
Materials And Methods:
Institutional review board approval and written informed consent were obtained. In 50 temporal bones, transverse and coronal single-detector row CT images were compared with transverse and reformatted coronal multi-detector row CT images obtained of additional 50 temporal bones. Two radiologists evaluated images. Visibility of 50 landmarks was scored with a five-point quality rating scale. Fisher exact test, kappa statistics, and Mann-Whitney U test were used to evaluate imaging technique and landmark visibility.
Results:
In delineating landmarks, total interobserver agreement was higher (P < .001) for transverse multi- than for single-detector row CT images. In 60% of landmarks, interobserver agreement was higher (P < .001) for transverse multi- than for single-detector row CT images. In 20% of landmarks, there was no difference, and in another 20% of landmarks, interobserver agreement was higher (P < .01) for single-detector row CT. Total interobserver agreement was higher (P < .01) for coronal multi-detector row reformations than for coronal single-detector row images. In 58% of landmarks, interobserver agreement was higher (P < .001) for coronal multi-detector row reformations than for coronal single-detector row images, while there was no difference in 8%. In 34% of landmarks, interobserver agreement was higher (P < .001) for coronal single-detector row images. Frequency of detected landmarks was higher for transverse (82%) and coronal (88%) multi-detector row images than for corresponding single-detector row images. In 72% of landmarks, transverse multi-detector row images were (P < .05) superior to corresponding transverse single-detector row images in landmark delineation. In 56% of landmarks, reformatted coronal multi-detector row images were (P < .05) superior to coronal single-detector row images in landmark delineation.
Conclusion:
Multi-detector row CT images, including reformations, better delineate temporal bone anatomy than do single-detector row CT images.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Cranial Bones: Lateral View
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...