Related Experiment Video
Updated: Aug 17, 2026

A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
Negative interference in cardiac troponin I immunoassays by circulating troponin autoantibodies
Susann Eriksson1, Heidi Halenius, Kari Pulkki
1Department of Biotechnology, University of Turku, Turku, Finland. susann.eriksson@utu.fi
Background:
There are numerous potential sources of interference in immunoassays. Our aim was to identify the blood component that causes negative interference in cardiac troponin I (cTnI) immunoassays based on antibodies against the central part of cTnI.
Methods:
We isolated an interfering factor (IF) from a sample with low recovery of added cTnI, using several consecutive purification steps: caprylic acid precipitation, ammonium sulfate precipitation, and purification on Cibacron Blue gel and protein G columns. Purified IF was identified by gel electrophoresis and mass spectrometric analysis of protein bands. For the direct detection of human antibodies to cardiac troponin in serum samples, we developed immunoassays using three different anti-human immunoglobulin antibodies and measured troponin antibodies in samples with low and normal cTnI recovery.
Results:
Treatment with caprylic acid did not precipitate IF, but IF precipitated at 40% ammonium sulfate saturation. IF bound to a Cibacron Blue gel column, from which it was eluted with a linear salt gradient; it also bound to protein G. Gel electrophoresis of purified IF showed two major bands with molecular masses corresponding to the heavy (approximately 50 kDa) and light chains (approximately 25 kDa) of immunoglobulin, and their identities were confirmed by mass spectrometry. The presence of troponin-specific autoantibodies was confirmed in samples with low recoveries of cTnI by three different immunoassays. The median signals were significantly higher in 10 samples with low recovery than in 10 samples with normal recovery of cTnI (P < or = 0.007).
Conclusions:
Circulating autoantibodies to cTnI or other proteins of the troponin complex can be a source of negative interference in cTnI immunoassays.
More Related Videos
09:23Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Heart Failure Drugs: Inotropic Agents
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Myocarditis I: Introduction
Myocarditis II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome I: Introduction