Related Experiment Video
Updated: Aug 19, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy
Dan Xia1, John C Roeske, Lifeng Yu
1Department of Radiology, The University of Chicago, Chicago, IL.
Purpose:
To develop a hybrid approach to reduce computed tomography (CT) metal artifacts caused by the Fletcher-Suit applicator.
Methods And Materials:
Using the acquired raw projection data, the hybrid algorithm determines the separate contributions from the metal and non-metal objects. Next, reconstructions of metal and non-metal images are separately obtained from their estimated projections. A final image is formed by appropriately combining the individual images. Phantom and patient data are used to evaluate the performance of this method.
Results:
CT images reconstructed by use of the standard filtered-backprojection (FBP) algorithm contain significant artifacts even for small metal objects. However, images reconstructed using the hybrid algorithm contain virtually no artifacts. For metal objects with complex structures, the hybrid algorithm can also yield images containing fewer severe streak artifacts than those reconstructed using the FBP algorithm alone.
Conclusions:
These studies demonstrate that the hybrid approach can effectively reduce CT metal artifacts caused by the Fletcher-Suit applicator.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022