Related Experiment Video
Updated: Aug 19, 2026

BrainBeats as an Open-Source EEGLAB Plugin to Jointly Analyze EEG and Cardiovascular Signals
Published on: April 26, 2024
The corner frequencies of the ECG amplifier for heart rate variability analysis
Laszlo Hejjel1, Lorand Kellenyi
1Heart Institute, Medical Faculty, University of Pecs, Pecs, H-7624, Hungary. lhejjel@freemail.hu
Abstract:
Heart rate variability (HRV) analysis is considered a popular method both in clinical and research fields. However, several ignored technical artifacts may falsify its measurements. The current study investigates the effects of corner frequencies of the ECG amplifier on the precision of RR-interval detection. Clear or noise-corrupted ECG records with predefined parameters consisting of 21 cycles were generated, played back through analog filters and data-logged on a Pentium-based computer with a DaqBoard2000 data acquisition card. 0.1-10 Hz second-order high pass and 20-100 Hz fourth-order low pass Bessel and Butterworth filters were used. The RR-intervals were measured between seven reference points of the ventricular complexes before and after filtering. High and low pass at every frequency cutoff and with both filter types results in correct RR-intervals within 1 ms error. However, a lower cutoff below 1 Hz is needed to maintain ECG morphology. AC interference or Gaussian random noise can falsify the measured RR-intervals up to 16 or 34 ms, respectively. These errors may be reduced to 1-4 ms with appropriate low pass filters. A frequency range of 0.5-20 Hz for the ECG amplifier can be sufficient for HRV analysis reducing the errors from AC interference or random noise.
More Related Videos
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...