A comparative study of invasive and oscillometric methods of arterial blood pressure measurement in the anesthetized
P Ypsilantis1, V N Didilis, M Politou
1Laboratory of Experimental Surgery, Medical School, Democritus University of Thrace, Alexandroupolis, Greece. pipsil@med.duth.gr
Introduction:
The aim of this project was to evaluate the reliability and accuracy of direct, using the central ear artery (CEA), and oscillometric, using limb-cuffs, methods of arterial blood pressure (AP) measurement in the anesthetized rabbit.
Methods:
New Zealand rabbits were anesthetized using a xylazine-ketamine-isoflurane protocol. Using the abdominal aorta (ABA) as direct "gold standard" for AP measurements, ABA pressure readings, via femoral artery catheterization, were compared with those made simultaneously from the ascending aorta after median sternotomy. Thereafter, direct CEA as well as forelimb-(FL) and hindlimb-(HL) cuff oscillometric readings were compared with those made simultaneously from ABA.
Results:
The blood pressure in the ABA correlated with that from ascending aorta. Furthermore, CEA correlated with the ABA readings. Nevertheless, at high pressures, their divergence from "true" pressure tended to increase. Oscillometric readings at the FL site correlated well with "true" pressure while those at the HL site did not. Their divergence tended to increase at high pressures when using the FL site, while it varied when using the HL site. The accuracy of measurements was moderate for the FL site while poor for the HL site.
Discussion:
Our results suggest that the CEA can be readily used with high reliability and accuracy for direct AP measurements in the anesthetized rabbit. On the other hand, the FL-cuff oscillometric method should only be used for the evaluation of AP at low and normal pressure ranges.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.