Characterization of Sickling During Controlled Automated Deoxygenation with Oxygen Gradient Ektacytometry
Published on: November 5, 2019
Hemoglobin oxygen saturation discrepancy using various methods in patients with sickle cell vaso-occlusive painful
Shahid Ahmed1, Anita K Siddiqui, Cristina P Sison
1Saskatoon Cancer Center, University of Saskatchewan, Saskatoon, SK, Canada. sahmed@scf.sk.ca
Objective:
To evaluate agreement among various methods for measuring oxyhemoglobin (O2Hb) saturation in adult hypoxic patients with sickle cell disease (SCD) during painful vaso-occlusive crisis and to compare those results with a control group.
Patients And Methods:
The hemoglobin oxygen saturation was determined simultaneously by pulse oximetry (SpO2), co-oximetry [SO2 (functional oxyhemoglobin saturation) and FO2Hb (oxyhemoglobin fraction)] and by calculation (SaO2) using a normal O2Hb dissociation curve in 18 adult patients with SCD during vaso-occlusive crisis and 12 non-SCD patients with various cardiopulmonary diagnoses. The method proposed by Bland and Altman was used to evaluate agreement of various methods in each of the two groups.
Results:
Mean differences between various methods in patients with SCD were significantly larger than the control group. Limits of agreement (LOA) were also wider in the SCD group than in the control group. Mean bias between SpO2 and SO2, and SpO2 and FO2Hb in patients with SCD were -3.1 +/- 4.4 (LOA: -11.9 to 5.7) and 2 +/- 4.1 (LOA: -6.2 to 10.2) respectively, compared with -1.4 +/- 1.4 (LOA: -4.2 to 1.4) and 1.2 +/- 1.5 (LOA: -1.9 to 4.3) in the control group. A mean bias of -4.5 +/- 4 (LOA: -12.5 to 3.5) between SpO2 and SaO2 was noted in patients with SCD compared with -0.1 +/- 2.1 (LOA: -4.3 to 4.1) in the control group. The width of LOA for various methods in patients with SCD ranged from 9.8 to 17.6 compared with 1.3 to 8.4 in the control group.
Conclusion:
Patients with SCD during vaso-occlusive crisis have discrepancies in O2Hb saturation measurements by various methods. Abnormal pulse oximetry values in these patients should be interpreted cautiously and supplemented by arterial blood gas analysis and co-oximetry.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Transport in the Blood
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...