Related Experiment Video
Updated: Aug 11, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Temporal scanner thermometry: a new method of core temperature estimation in ICU patients
D Myny1, J De Waele, T Defloor
1Department of intensive care, Ghent University Hospital, Ghent, Belgium. dries.myny@uzgent.be
Background And Aims:
Temperature measurement is a routine task of patient care, with considerable clinical impact, especially in the ICU. This study was conducted to evaluate the accuracy and variability of the Temporal Artery Thermometer (TAT) in ICU-patients. Therefore, a convenience sample of 57 adult patients, with indwelling pulmonary artery catheters (PAC) in a 40-bed intensive care unit in a university teaching hospital was used.
Methods:
The study design was a prospective, descriptive comparative analysis. Body temperature was thereby measured simultaneously with the TAT and the Axillary Thermometer (AT), and was compared with the temperature recording of the PAC. The use of vasoactive medication was recorded.
Results And Conclusions:
Mean temperature of all measurements was: PAC: 37.1 degrees C (SD: 0.87), TAT 37.0 degrees C (SD: 0.68) and axillary thermometer: 36.6 degrees C (SD: 0.94). The measurements of the TAT and the PAC were not significantly different (man differnce: 0.14 degrees C; SD: 0.51; p = 0.33); whereas the measurements of the PAC and the AT differed significantly (mean difference: 0.46 degerees C; SD: 0.39; p < 0.001). Mean diference in PAC versus TAT analyses, between patients with vasopressor therapy (0.12 degrees C; SD: 0.55), and without vasopressor therapy (0.19 degrees C; SD: 0.48) was not statistically significant (p = 0.47).
Conclusion:
We can conclude that the temporal scanner has a relatively good reliability with an acceptable accuracy and variability in patients with normothermia. The results are comparable to those of the AT, but they do not seem to be sufficient to prove any substantial benefit compared to rectal, oral or bladder thermometry.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...