Related Experiment Video
Updated: Jan 19, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Evaluation of arterial endothelial function using transit times of artificially induced pulses
Jonathan S Maltz1, Thomas F Budinger
1Department of Functional Imaging, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720, USA.
Abstract:
Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. The most widely employed non-invasive measure of endothelial function involves brachial artery (BA) diameter measurement using ultrasound imaging before and after several minutes of blood flow occlusion. The change in arterial diameter is a measure of flow-mediated vasorelaxation (FMVR). The high between-laboratory variability of results and cost of instrumentation render this technique unsuitable for routine clinical use. We induce artificial pulses at the superficial radial artery using a linear actuator. An ultrasonic Doppler stethoscope detects these pulses 10-30 cm proximal to the point of pulse induction. The delay between pulse application and detection provides the pulse transit time (PTT). By measuring PTT before and after 5 min of BA occlusion and ensuing reactive hyperemia, FMVR may be measured based on the changes in PTT caused by changes in vessel caliber, smooth muscle tone and wall thickness. We (1) validate the sensitivity of this technique to arterial wall tone using sublingual nitroglycerin and (2) compare measurements of endothelial function to ultrasound BA diameter measurements in 12 human subjects. The PTT-based method is verified to measure arterial wall tone and is shown to provide 37% greater sensitivity (p < 0.05) to FMVR than BA diameter measurements. By measuring the change in pulse transit time before and after endothelial stimulus, a sensitive, reproducible and convenient measure of endothelial function may be obtained at a low cost.
Related Concept Videos
10:03Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension
09:40Induction of Right Ventricular Failure by Pulmonary Artery Constriction and Evaluation of Right Ventricular Function in Mice
07:49Molecular Analysis of Endothelial-mesenchymal Transition Induced by Transforming Growth Factor-β Signaling
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
06:15Evaluation of Bioenergetic Function in Cerebral Vascular Endothelial Cells
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants

