Related Experiment Videos
Technetium-99m HM-PAO single photon emission computed tomography imaging in transient global amnesia
P Laloux1, C Brichant, F Cauwe
1Department of Neurology, Mont-Godinne Hospital, University of Louvain, Yvoir, Belgium.
Abstract:
Five right-handed patients with pure transient global amnesia were evaluated with technetium-99m hexamethylpropyleneamine oxime single photon emission computed tomography after the amnesic attack. Independent of the interval between the procedure and the amnesic episode, single photon emission computed tomography demonstrated a decreased cerebral blood flow in the left temporal lobe in one patient and in the left parietotemporal region in three patients, with a more marked reduction in the temporal lobe. The remaining three patients were normal. A control single photon emission computed tomographic study was carried out in one patient 3 months after the amnesic attack and showed a left-sided persistent temporal hypoperfusion. These findings suggest that in some patients, transient global amnesia can be due to a vascular mechanism requiring strong investigations for vascular risk factors and appropriate treatment. During a follow-up period of 12 to 32 months, none of the patients with regional hypoperfusion suffered cerebrovascular events, suggesting that single photon emission computed tomography has no predictive value for further stroke.