Related Experiment Video
Updated: Aug 18, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Revision total knee arthroplasty with modular components inserted with metaphyseal cement and stems without cement
Christopher L Peters1, Jill Erickson, Robert G Kloepper
1Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
Abstract:
The clinical and radiographic outcomes of 50 consecutive revision total knee arthroplasties in 47 patients, placed with metaphyseal cemented femoral and tibial components with press-fit cementless stems, were reviewed at 36-month average follow-up. Revision was performed for aseptic loosening (11/50), infection (17/50), periprosthetic fracture (8/50), component failure (6/50), instability (6/50), and malalignment (2/50). The press-fit cementless stems were 80 to 160 mm in length and tightly contacted the endosteum of the metadiaphyseal areas. Four (9%) knees were re-revised for infection, zero for aseptic loosening. The average modified Hospital for Special Surgery knee score improved from 49 to 87. One patient (2%) reported thigh pain, and 1 reported leg pain. Metaphyseal cemented revision total knee components with press-fit cementless femoral and tibial stems were not associated with significant thigh and leg pain.